Welcome to Junsi iCharger 4010DUO ================================ Please read the release history in the help system for information about earlier releases. //////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////// // Version: V2.18 // // Date of Release: 2016/12/23 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add the feature to support the LiHV battery. Bug Fixes ========= 165: Solve the bug of 1600 error due to the impact of two channels. 165: Solve the bug of Pin Reset when power on. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.17 // // Date of Release: 2015/01/12 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add the feature of turn off beep automatically when battery is removed after the charging completed. Bug Fixes ========= 161: Correct the bug to show wrongly 2003 error when regenerative discharge in synchronous. 162: Solve the bug of the clock fails to work when two channels discharge simultaneously. 163: Solve the problem in some cases to start charging, the current shows negative value. 164: Solve one bug of anti-sparking program. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.16 // // Date of Release: 2014/08/25 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 160: Correct the "2120" error triggered accidentally. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.15 // // Date of Release: 2014/08/01 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 157: Change the default value of discharge voltage for Nixx battery from 0.1V to 0.8V. 158: Solve the invalid problem of " detect if the main port and the balance port charging matching" in the V2.14. 159: Solve the balance regenerative discharge never completes problem. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.14 // // Date of Release: 2014/06/27 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Increase the number of display for program running. * Add the feature to detect if the main port and the balance port charging matching. Bug Fixes ========= 150: Revise the PID control parameter, and weaken the fluctuation problem of low charge current. 151: Improve the problem of endless low charge current 152: Correct "Balance Over Charge" does not start problem. 153: When user sets the "user " from "Servo Test", the parameter is failed to check reasonably. 154: Correct the problem that fails to restart the offline resistance measurement after charging. 155: Correct the instantaneous current display problem when starts charging. 156: Solve the problem that fails to display sometimes when connecting big internal resistance load voltage battery. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.13 // // Date of Release: 2014/03/21 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Added a protected program in "regenerative to input mode", if the input power is the power supply, the charger will detected automatically, and shut down automatically, to avoid damaging the power supply. Bug Fixes ========= 148: Fix the charge and discharge cycle problem. 149: Fix the startup problem of charging and discharging synchronization of V2.12. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.12 // // Date of Release: 2014/02/20 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Modify the current setting step. * Ignore the knob rolling signal before time within 50ms, and after time within 500ms by pressing the knob. avoid some wrong operation. Bug Fixes ========= 140: Fix some display problems. 141: Improve small current fluctuation problem of discharge. 142: Correct "1401" error caused by battery trickle occasionally. 143: modify the "Banlance Over Charge" setting to 50mV max. 144: Improve shutdown control program. 145: Modify the discharge capacity limit default from 120% to 90%. 146: Correct "1401" error bug caused by regenerative discharge occasionally. 147: Correct the conflict of loading configuration files on SD card. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.11 // // Date of Release: 2013/12/26 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add the "Knob sensitivity" setup. Bug Fixes ========= 136: Correct the device reboots problem when transfers the Log files. 137: Correct the problem of the missing character "_" when inputs file name. 138: Correct the bug of time display. 139: Modify the version display format "x.x.x" to "x.xx". Note ==== //////////////////////////////////////////////////////////////// // Version: V2.10 // // Date of Release: 2013/11/13 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add the "Charging battery" into the entry of "Channel Join" of Channel Regenerative Discharge. * Add the capacity indicator of the input power supply. * Add the capacity limit of the Regenerative to input. * Add the Cycle Mode option: "CHG->DCHG CHG" "DCHG->CHG DCHG" "CHG->DCHG STO" "DCHG->CHG STO". Bug Fixes ========= 133: Correct the bug of Cycle charge when the Channel Regenerative Discharge starts. 134: Improve the anti-sparking program. 135: Solve the white screen problem when powering on sometimes. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.09 // // Date of Release: 2013/09/30 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 132: Correct the bug for 2006 error triggered accidently. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.08 // // Date of Release: 2013/09/27 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 131: Correct the Cycle defect problem of NiZn battery. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.07 // // Date of Release: 2013/09/23 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 130: Solve the problem of V2.06: when running storage on the CH1, the CH2 cannot work normally. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.06 // // Date of Release: 2013/09/11 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ Bug Fixes ========= 128: Solve the charger frozen problem with V2.05. 129: Solve the problem of current increasing slowly on the regenerative mode to channel. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.05 // // Date of Release: 2013/08/27 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add PC control interface. * Add the feature to support NiZn battery. * Add the feature of anti-sparking on output. Bug Fixes ========= 121: Revise the adjustment step of end current percentage to 1. 122: Revise charging PID parameter. 123: Correct the misspelled "Prees"->"Press" on the initial interface. 124: After limiting 64 memories, "Add" button is invalid. 125: Correct the bug of end current and safety capacity when running synchronous mode. 126: Correct the bug of fan temperature controlling. 127: Prohibit to pop up the modify menu on "Balance Only" mode. Note ==== //////////////////////////////////////////////////////////////// // Version: V2.04 // // Date of Release: 2013/04/18 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add "Balance charge end setup" option for Lixx * Balance speed can be selected directly in balance mode * The capacity adjustment step from 100mAh to 50mAh * Change the system display color and enhance contrast Bug Fixes ========= 115:Solve the problem of may burning in small current circumstances 116:Correct the display bug for battery number 117:The rate of increase of the discharge current is increased 118:Increase the servo speed test current detection range, improved speed algorithm 119:Solve the problem of current fluctuation when input and output voltage approaches 120:Correct the occasional 1300 error in Channel regenerative mode. Note ==== //////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////// // Version: V2.03 // // Date of Release: Unpublished // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add servo types selection into servo test, available for testing other types such as 760us. Bug Fixes ========= 112: Correct the "Chg Mode" setting bug for Nixx and Pb battery 113: Disable the end current judgment in balance charge 114: Correct the misspelled "Waitting" to "Waiting". Note ==== //////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////// // Version: V2.02 // // Date of Release: 2013/02/04 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add "Roll-Over" feature into List controls. * Add PID control to enhance the control precision for CC, CV. * The sequence number of battery cells can be lit to display only by connecting. Bug Fixes ========= 104: Revise the display problem when unplug the balance port on Balance Only Mode. 105: Revise the problem that fails to terminate sometimes on Balance Only Mode. 106: Revise the problem for large fluctuation of current ripple when input voltage is close to output voltage. 107: Correct the bug for 2100 error triggered accidently on Channel Regenerative Mode. 108: Correct the bug for revising the end voltage online when discharging Li battery. 109: Correct the bug for capacity mAh of Info page and safety time display overflow. 110: Weaken the screen flashing when switching back to the main interface. 111: Correct one bug for refreshing on the IR interface. Note ==== //////////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////////// // Version: V2.01 // // Date of Release: 2012/12/28 // // Owner: CWF // //////////////////////////////////////////////////////////////// Part support ============ 4010DUO New Features ============ * Add "Delect All" into Log file. Bug Fixes ========= 100. Correct the bug for overflow and current C-value display. 101. Correct the bug for marking simultaneously in the Windows title. 102. Correct the bug after transferring the Log file, AD sampling was frozen sometimes. 103. Correct the bug when NiXX trickle charges, the capacity was set to 0. Note ====